Successful commercial ceramic hotelware testwork results
Released
Released
Announcement PDF
Successful commercial ceramic hotelware testwork results
Testwork results confirm kaolin from the GWP and Chairlift as highly competitive
against established premium kaolins in high-value commercial ceramic hotelware
body and glaze formulations
High-value market with potential to be value-accretive and support future expansion
Andromeda Metals Limited (ASX: ADN) (Andromeda, the Company) is pleased to announce the results
of ceramic hotelware testwork results confirming kaolin from both the Great White Project (GWP) and
the Chairlift Deposit1 as highly competitive, when compared to existing kaolins used in the
manufacture of high-value commercial hotelware.
To support product validation of our high-quality kaolin products for use in high-value market
segments, three (3) samples of kaolin were sent for testing and evaluation for their suitability in
commercial hotelware body and glaze formulations.
The 3 samples from Andromeda were:
• 2 samples of Great White CRM™ products:
o Great White CRM™P marketed as for use in porcelain tableware
o Great White CRM™X which is representative of Stage 1A+ production; and
• Chairlift CRM – a representative processed sample from the Chairlift Deposit which was
previously identified as well-suited for the high-quality porcelain ceramics market.
To assess the suitability of the samples for use in commercial hotelware body formulations, the three
samples were used in the standard commercial hotelware body formulations currently used by a major
ceramics manufacturer in Stoke-on-Trent, United Kingdom, which has been established since the late
18th century and through a global distribution network.
The three samples were assessed and benchmarked against formulations with other kaolins, including
the sole kaolin used by the manufacturer and an additional six (6) other commercial kaolin samples
from Europe.
Separately, the three samples from Andromeda were evaluated for their suitability in commercial
hotelware glaze formulations and benchmarked against the standard kaolin used by the UK
manufacturer.
1
Refer to ADN ASX dated 16 November 2023 titled Chairlift Kaolin Deposit Mineral Resource Estimate.
Andromeda Metals Limited ASX: ADN
ASX Announcement
10/431 King William Street
Adelaide, SA 5000
Tel:+61 8 7089 9800
ir@andromet.com.au
30 October 2025
ABN
75 061 503 375
Andromeda Metals Limited | 2
All the testwork was completed at one of the UK’s leading mineral processing companies which is
based in Stoke-on-Trent, where the majority of the UK’s ceramic tableware is manufactured.
Key findings from the testwork2 are:
• All 3 of Andromeda’s samples were characterised as being low in iron (Fe2O3) and titanium
(TiO2) and suitable for use in ceramic body and glaze hotelware formulations
• Great White CRM™P and Great White CRM™X gave superior results, through:
o Lowest fired b values (yellowness) in body formulations, and
o Being the only samples demonstrating superior L*, a*, b* brightness and colour co-
ordinate results than the standard kaolin used in ceramic body formulations.
These positive results open additional sales opportunities in the premium commercial ceramics
hotelware body and glaze market segments, with the potential to support future expansions of
production from the Great White Project.
Figure 1 - Fired discs of commercial ceramic hotelware body formulation - (l to r) Chairlift CRM (CRM 001), Great White
CRM™P (CRM 19) and Great White CRM™X (CRM 21)
2
Evaluation of refined Kaolin in commercial ceramic hotelware for Andromeda Metals, First Test Minerals, July/August 2025.
Andromeda Metals Limited | 3
Figure 1 - Glazed discs after firing at 1080°C - UK standard glaze - (l to r) Chairlift CRM (CRM 001), Great White CRM™P
(CRM 19) and Great White CRM™X (CRM 21)
Sarah Clarke, Andromeda’s Acting Chief Executive Officer said:
“While Andromeda continues to progress the Great White Project towards a final investment decision,
we continue to look for additional value-accretive growth opportunities to support future expansion
beyond the initial Stage 1A+ development.
“The strength of these testwork results supports new sales opportunities into the high-value ceramic
hotelware market, which has the potential to be value-accretive and support future expansion.”
This announcement has been approved for release by the Board of Andromeda Metals Limited.
For more information about the Company and its projects, please visit our website,
www.andromet.com.au or contact:
Manager, Investor Relations & Corporate Affairs
Patrick Sinclair
T: 08 7089 9819
M: 0403 708 431
E: Patrick.Sinclair@andromet.com.au
COMPETENT PERSON STATEMENT
Information in this announcement that relates to exploration results is based on information compiled and thoroughly
reviewed by Mr Eric Whittaker who is a Member of the Australasian Institute of Mining and Metallurgy (MAusIMM). Mr
Whittaker is the Chief Geologist of Andromeda Metals Limited and has sufficient experience relevant to the style of
mineralisation and type of deposit under consideration and to the activity which he is undertaking to qualify as a
Competent Person as defined in the 2012 Edition of the Australasian Code for Reporting of Exploration Results, Mineral
Resources and Ore Reserves (the “JORC Code”). Mr Whittaker has 30 years of experience in the mining industry. Mr
Whittaker consents to the information in the form and context in which it appears. Mr Whittaker holds Performance
Rights in the Company and is entitled to participate in Andromeda’s employee incentive plan.
FORWARD-LOOKING STATEMENTS
This document contains or may contain certain forward-looking statements and comments about future events, that
are based on Andromeda's beliefs, assumptions and expectations and on information currently available to
management as at the date of this document. Often, but not always, forward-looking statements can generally be
identified by the use of forward-looking words such as "may", "will", "expect", "plan", "believes", "estimate", "anticipate",
"outlook", and "guidance", or similar expressions. Such statements are only expectations or beliefs and are subject to
Andromeda Metals Limited | 4
inherent risks and uncertainties which could cause actual values, results or performance achievements to differ
materially from those expressed or implied in this presentation. Where Andromeda expresses or implies an expectation
or belief as to future events or results, such expectation or belief is expressed in good faith and on a reasonable basis.
No representation or warranty, express or implied, is made by Andromeda that the matters stated in this presentation
will in fact be achieved or prove to be correct. Except as required by law, Andromeda undertakes no obligation to
provide any additional or updated information or update any forward-looking statements, whether on a result of new
information, future events, results or otherwise. Readers are cautioned against placing undue reliance on forward-
looking statements. These forward-looking statements are not guarantees of future performance and involve known
and unknown risks, uncertainties, assumptions and other important factors, many of which are beyond the control of
Andromeda, the directors, and management of Andromeda.
Summary findings of the trials
Following is a summary of the findings of the trials successfully validating Great White and Chairlift CRM
products in commercial ceramic hotelware body and glaze recipes.
Samples
Three 5 kg kaolin samples of Andromeda product were provided to Ceramic Support Services in Stoke-
on-Trent. The samples included:
• Chairlift CRM
• Great White, CRM™P – marketed as for use in porcelain tableware
• Great White, CRM™X – representative of the Great White Project’s Stage 1A+ production
Chemistry
First Test Minerals submitted sub-samples of Andromeda’s products to AMG Chrome, a UKAS-accredited
laboratory, for chemical composition analysis. Each sample was fused into a glass bead by mixing with
lithium tetraborate and heating to > 1000 °C, then analysed by X-ray fluorescence (XRF). Loss on Ignition
(LOI) was measured at 1000 °C.
The comparison kaolins used in the testwork were a selection of well-established materials for hotelware
and porcelain production across Europe, and in several cases (such as the Kaopearl, Standard Porcelain,
and OKA kaolin products) are used globally.
Against these commercial benchmarks, the Andromeda samples performed strongly, exhibiting high
alumina (Al2O3) content and low concentrations of ferric (Fe2O3) and titanium (TiO2) oxides (refer to
results in Table 1).
Table 1. Chemical Composition of the kaolin samples used in the trials
Kaolin Product SiO2
(%)
Al2O3
(%)
Fe2O3
(%)
TiO2
(%)
CaO
(%)
MgO
(%)
Na2O
(%)
K2O
(%)
LOI
(%)
Andromeda Chairlift CRM 47.28 37.66 0.48 0.11 <0.05 0.12 <0.05 0.56 13.65
Andromeda Great White CRM™P 46.89 38.21 0.37 0.37 <0.05 <0.05 <0.05 0.43 13.75
Andromeda Great White CRM™X 46.78 38.81 0.26 0.20 <0.05 <0.05 <0.05 0.19 13.99
KaoPearl 47.6 37.1 0.56 0.05 0.06 0.32 0.12 1.20 13.20
OKA 49.5 35.5 0.43 0.17 0.20 0.26 0.01 0.30 13.40
Standard Porcelain 48.0 36.5 0.72 0.04 0.07 0.30 0.10 1.74 12.50
Regal 49.0 36.0 0.64 0.01 0.10 0.30 0.10 2.20 11.70
Stannon 48.0 36.5 1.00 0.05 0.07 0.30 0.10 2.00 12.00
CC31 48.0 35.7 0.95 0.09 0.10 0.20 0.10 2.80 11.60
Diamond Ultrabright 47.0 37.5 0.80 0.03 0.02 0.20 0.08 2.30 12.50
Andromeda Metals Limited | 5
These analyses further demonstrate that kaolin from the Great White deposit is an ideal feedstock for the
production of High Purity Alumina (HPA), due to its relatively low concentrations of key deleterious
elements, particularly alkali metals (Na and K) and alkaline earth metals (Ca and Mg) (refer to Figure ).
When comparing Great White CRM™X to OKA, Great White CRM™x contains less than a quarter of the
alkali and alkaline earth metal impurity content that would need to be extracted to produce HPA.
Figure 2. Alumina grades of tested kaolins versus key alkali metals and alkaline earth metals
Particle Size of the Andromeda and Commercial Kaolins
Particle size was measured using both laser diffraction (Malvern) and Sedigraph analysis. As kaolin
particles are platy, particle size is usually measured by rate of settlement using a Sedigraph. Laser
diffraction is more suited to non-plastics such as quartz and feldspars which have rounded particles.
Typically, laser diffraction reports a coarser distribution than Sedigraph, and there is no direct correlation
between the two methods.
Particle-size distributions are commonly expressed as D10, D50, D90:
• D10: 10% of particles are smaller than this size (µm)
• D50: median particle size (µm)
• D90: 90% of particles are smaller than this size (µm)
Laser diffraction estimates size statistically by analysing light-scattering patterns at multiple angles rather
than measuring particles individually.
Kaolin manufacturers commonly specify % <2 µm by Sedigraph on Technical Data Sheets (TDS). Values
quoted on TDS are compared with results for the CRM samples in Table 2.
Chairlift CRM
Great White
CRMp Great White
CRMx
KaoPearl
OKA
Standard
Porcelain
Regal
Stannon
CC31
Diamond
Ultrabright
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
35.00 35.50 36.00 36.50 37.00 37.50 38.00 38.50 39.00
CaO+MgO+Na
2
O+K
2
O
(%)
Al2O3 (%)
Alumina vs CaO+MgO+Na2O+K2O
Andromeda Others
Andromeda Metals Limited | 6
Table 2. Particle Size of kaolin samples by Malvern Laser Diffraction and Sedigraph
Particle Size Distribution Malvern Laser Diffraction Sedigraph
Kaolin Product D10
(µm)
D50
(µm)
D90
(µm)
< 2 µm (%)
Andromeda Chairlift CRM 0.86 3.15 14.3 79
Andromeda Great White CRM™P 1.26 7.27 29.5 67
Andromeda Great White CRM™X 1.67 9.89 80.7 74
KaoPearl 1.18 5.65 38.0 85
OKA 0.85 2.53 6.69 68
Standard Porcelain 1.08 4.96 15.9 70
Regal 1.30 5.39 16.9 60
Stannon 1.97 8.15 22.9 39
CC31 1.07 5.08 18.5 49
Diamond Ultrabright 1.71 6.97 19.3 45
Preparation and Evaluation of Ceramic Bodies
Standard Body Recipe
The reference recipe is a hotelware body currently manufactured by a major ceramics producer in
Stoke-on-Trent (established 225 years ago and operates 800 distributors in 80 countries). The standard
formulation uses Kaopearl as the sole kaolin (refer to Table 3). Percentage, grade and supplier details for
ball clay, feldspar, quartz and alumina are omitted for due to confidentiality.
Table 3. Composition of the Standard Commercial Hotelware
in addition to in addition in addition in addition
Kaolin Kaopearl France 35
Ball Clay - UK -
Feldspar - Germany -
Quartz - UK -
Alumina - UK -
Chemical Composition of Prepared Bodies
Kaopearl and the three Andromeda bodies were analysed by AMG-Chrome. Other blends were
calculated by applying TDS XRF specifications relative to Kaopearl, assuming a 35% addition rate (refer to
Table 4).
Table 4. Chemical Composition of the Prepared Ceramic Bodies
Kaolin Product SiO2
(%)
Al2O3
(%)
Fe2O3
(%)
TiO2
(%)
CaO
(%)
MgO
(%)
Na2O
(%)
K2O
(%)
BaO
(%)
P2O5
(%)
LOI
(%)
Andromeda
Chairlift CRM
58.19 34.13 0.20 0.09 0.06 0.12 0.09 2.05 0.06 <0.05 5.06
Andromeda
Great White
CRM™P
57.97 34.23 0.16 0.18 0.06 0.09 0.10 1.99 0.07 <0.05 5.28
Andromeda
Great White
CRM™X
57.94 34.58 0.12 0.12 0.07 0.09 0.09 1.91 0.06 <0.05 5.34
KaoPearl 58.26 33.92 0.19 0.06 0.08 0.18 0.11 2.30 0.06 0.06 4.98
OKA 58.95 33.36 0.14 0.10 0.13 0.16 0.07 2.00 0.06 0.06 4.99
Standard
Porcelain
58.40 33.71 0.20 0.05 0.08 0.18 0.10 2.49 0.06 0.06 4.78
Regal 58.75 33.54 0.21 0.05 0.09 0.18 0.10 2.65 0.06 0.06 4.46
Stannon 58.40 33.71 0.34 0.06 0.08 0.18 0.11 2.58 0.06 0.06 4.56
CC31 58.40 33.43 0.32 0.07 0.09 0.14 0.11 2.86 0.06 0.06 4.46
Diamond
Ultrabright
58.02 34.06 0.27 0.06 0.07 0.14 0.10 2.68 0.06 0.06 4.78
Andromeda Metals Limited | 7
All Andromeda blends compare well with the commercial benchmarks:
• Chairlift CRM closely matches the Kaopearl standard, with slightly lower K2O.
• Great White CRM™P and Great White CRM™X are also good matches, with minor differences:
Fe2O3and K2O lower, TiO2 slightly higher.
Particle Size of Kaolin Samples and Prepared Bodies
Laser diffraction (Malvern) was used to measure particle size of the prepared bodies. For plastic bodies,
laser diffraction performs well as a quality-control tool to maintain consistency, (refer to Table 5).
Table 5. Particle Size of the “prepared body” by Malvern Laser Diffraction
Kaolin Product D10
(µm)
D50
(µm)
D90
(µm)
Andromeda Chairlift CRM 1.03 4.68 20.5
Andromeda Great White
CRM™P
1.20 6.43 26.1
Andromeda Great White
CRM™X
1.31 6.71 32.0
KaoPearl 1.07 5.12 25.4
OKA 0.94 3.10 23.0
Standard Porcelain 1.16 5.40 19.5
Regal 1.23 5.66 19.3
Stannon 1.55 7.54 24.3
CC31 1.26 6.08 23.1
Diamond Ultrabright 1.71 6.97 19.3
Gradient Kiln Firing
Pressed discs from each body were dried at 110 °C, then fired in a thermal-gradient kiln across typical
commercial temperatures: 1210-1290 °C.
Evaluation of Fired Discs
At each temperature, discs were measured for:
• Water absorption (WAB, %)
• Linear contraction (%)
Alkalis (Na₂O, K₂O, predominantly K₂O) act as fluxes during firing, generally increasing contraction and
reducing WAB (refer to Table 6). Finer particle size can modestly enhance fluxing (increasing contraction
and lowering WAB), but K₂O content exerts the stronger influence (refer to Table 7).
Table 6. Water absorption (%)
Kaolin Product 129
0°C
1275
°C
1260°C 1245°C 1230°C 1210°C
Andromeda Chairlift CRM 1.05 3.42 6.98 7.83 10.45 15.11
Andromeda Great White
CRM™P
5.84 6.13 11.15 11 14.35 19
Andromeda Great White
CRM™X
5.34 6.79 11.05 11.11 14.1 19.24
KaoPearl 0.25 0.29 3.23 4.66 6.53 8.54
OKA 1.88 3.38 6.52 8.28 10.51 14.07
Standard Porcelain 0.04 0.05 3.25 3.73 5.7 8.91
Regal 0.05 0.05 2.75 3.46 5.57 9.04
Stannon 0.1 0.29 5.85 6.11 8.35 13.33
CC31 0.05 0.09 1.57 2.91 4.92 8.73
Diamond Ultrabright 0.34 0.61 5.55 6.35 7.87 10.9
Andromeda Metals Limited | 8
Table 7. Contraction (%)
Kaolin Product 1290°C 1275°C 1260°C 1245°C 1230°C 1210°C
Andromeda Chairlift CRM 14.5 14.0 13.0 12.0 10.5 9.5
Andromeda Great White CRM™P 15.0 14.0 12.5 12.0 10.5 9.0
Andromeda Great White CRM™X 14.5 14.0 12.5 11.5 10.5 9.5
KaoPearl 14.0 13.3 13.0 12.0 11.5 10.0
OKA 14.0 13.5 12.5 11.5 10.0 9.0
Standard Porcelain 13.5 13.0 12.5 12.0 11.5 10.0
Regal 12.5 12.5 11.5 11.0 11.0 9.5
Stannon 13.5 12.5 12.5 11.5 11.0 9.0
CC31 15.0 15.0 14.5 13.5 13.5 11.5
Diamond Ultrabright 14.0 13.0 13.0 12.5 12.0 10.0
Andromeda grades show similar contraction to the Kaopearl standard, with higher WAB, consistent with
lower K₂O. This is not problematic for commercial trials, given a small increase in feldspar could be used
to compensate. Minor formulation adjustments are standard when introducing new raw materials.
CIELAB (L*a*b*) Brightness and Colour Coordinates
Colour was measured at 1290 °C, representative of factory heat/work input in tunnel kiln firing, Table 8.
Thermal expansion (linear) was also measured at 1290 °C; body–glaze expansion matching is critical to
avoid cracking or crazing.
Samples were measured by spectrophotometer for CIE L*, a*, b:
• L*: lightness (0 = black, 100 = white)
• a*: green (−) to red (+)
• b*: blue (−) to yellow (+)
For fired tableware the target is to keep the yellowness factor (b value) as close to 0 as possible
(“blue-white” rather than “yellow-white”) and often a slight green tendency (more negative a*) rather
than red.
Colour outcomes typically reflect body chemistry:
• Lower Fe2O3 and TiO2 → higher L* and lower b*.
• Higher K2O promotes fluxing-in of Fe2O3 and TiO2 during firing, which can reduce L* and raise b*.
Overall comparison:
• All three Andromeda blends perform well against the Kaopearl standard.
• Great White CRM™P and Great White CRM™X deliver the best overall colour results, followed by
OKA.
Notably, Kaopearl’s low b* value (4.49) is surpassed only by Andromeda’s Great White CRM™P and
Great White CRM™X products, which can be evidenced in Table 8.
Table 8. Thermal expansion and L* a* b* brightness and colour co-ordinates
Kaolin Product
Thermal
Expansion
L* a* b*
Chairlift CRM 0.336 95.47 -0.19 5.27
Great White CRM™P 0.317 96.20 -0.40 4.48
Great White CRM™X 0.313 96.58 -0.31 3.40
Kaopearl 0.322 94.78 -0.40 4.49
OKA 0.323 96.14 -0.18 4.71
SP 0.322 93.16 -0.15 6.60
Regal 0.319 91.48 -0.47 5.49
Andromeda Metals Limited | 9
Stannon 0.307 92.02 -0.35 8.84
CC31 0.336 88.15 -0.45 7.03
Diamond
Ultrabright
0.323 91.62 -0.40 6.58
Glaze Trials
Standard and trial glaze formulations were applied to fired discs prepared using the Kaopearl body
recipe.
The standard commercial glaze consists of a frit supplied by Esmaltes (Spain) with 10% Regal kaolin. For
the trial glazes, the Regal kaolin was replaced with Andromeda’s products.
Frits were wet-milled in cold water to achieve a specific particle size, then kaolin was added at 10% by
weight and thoroughly mixed. Each glaze suspension was prepared in 1 L batches, adjusted to a pint
weight of 31 oz (commercial standard). (For details on pint weight, see: Northern Kilns Guide
https://northernkilns.com/assets/documents/pint-weight.pdf).
The primary role of kaolin in glaze is to maintain suspension and prevent settling; fine, platy clays are
ideal. Any halloysite present in the Andromeda samples may enhance suspension due to its air- or water-
filled tubular structure, providing buoyancy. After one week of standing, all four suspensions showed only
minor settling, easily corrected by gentle shaking. No hard-settled residue was observed.
Discs were sprayed with the standard and trial glazes to achieve a consistent application weight (per
m²), oven-dried at 110 °C, and fired to 1080 °C.
The fired discs were evaluated for appearance and CIELAB colour coordinates. Results show that
Andromeda grades perform comparably to Regal, the current commercial standard, in terms of
brightness and colour, Table 9.
Table 9. CIELAB (L*a*b*) brightness and colour co-ordinates for glaze applications
Company Andromeda Andromeda Andromeda Leading European
provider
Kaolin Chairlift CRM Great White
CRM™P
Great White
CRM™X
Regal
L* 93.09 94.44 94.23 90.48
a* -0.83 -0.69 -0.75 -0.75
b* 4.83 4.69 5.03 5.04
No issues were encountered during glaze preparation, storage, spraying, or firing. The fired glaze
surfaces were smooth, well-fitted, and free from cracking or crazing.
Conclusions
Testwork conducted in Stoke-on-Trent demonstrated that Andromeda’s products: Chairlift CRM, Great
White CRM™P and Great White CRM™X, perform effectively as substitutes for Kaopearl in a current
commercial hotelware body formulation.
Additionally, all three of Andromeda’s products were successfully used in a commercial glaze
formulation, replacing Regal kaolin without any negative impact on processing or fired properties,
significantly improving whiteness.
JORC CODE, 2012 EDITION – TABLE 1
Section 1 Sampling Techniques and Data
(Criteria in this section apply to all succeeding sections.)
Sampling
techniques
• Nature and quality of sampling (eg cut channels, random chips, or specific specialised industry
standard measurement tools appropriate to the minerals under investigation, such as down hole
gamma sondes, or handheld XRF instruments, etc). These examples should not be taken as
limiting the broad meaning of sampling.
• Include reference to measures taken to ensure sample representivity and the appropriate
calibration of any measurement tools or systems used.
• Aspects of the determination of mineralisation that are Material to the Public Report.
• In cases where ‘industry standard’ work has been done this would be relatively simple (eg ‘reverse
circulation drilling was used to obtain 1 m samples from which 3 kg was pulverised to produce a 30
g charge for fire assay’). In other cases more explanation may be required, such as where there is
coarse gold that has inherent sampling problems. Unusual commodities or mineralisation types
(eg submarine nodules) may warrant disclosure of
detailed information.
• The Andromeda products used in the “Evaluation of
Refined Kaolin in Commercial Ceramic Hotelware” were
sourced from the Great White and Chairlift Kaolin Projects.
• The ceramic body formulation used in the Stoke-On-Trent
trials are commercial in confidence.
Drilling
techniques
• Drill type (eg core, reverse circulation, open-hole hammer, rotary air blast, auger, Bangka, sonic,
etc) and details (eg core diameter, triple or standard tube, depth of diamond tails, face-sampling
bit or other type, whether core is oriented and if so, by what method, etc)...
• Not applicable, as the testwork was conducted on
manufactured products.
Drill sample
recovery
• Method of recording and assessing core and chip sample recoveries and results assessed.
• Measures taken to maximise sample recovery and ensure representative nature of the
samples.
• Whether a relationship exists between sample recovery and grade and whether sample bias may
have occurred due to preferential loss/gain of fine/coarse material...
• Not applicable, as the testwork was conducted on
manufactured products.
Logging • Whether core and chip samples have been geologically and geotechnically logged to a level of
detail to support appropriate Mineral Resource estimation, mining studies and metallurgical studies.
• Whether logging is qualitative or quantitative in nature. Core (or costean, channel, etc)
photography.
• The total length and percentage of the relevant intersections logged...
• Not applicable, as the testwork was conducted on
manufactured products.
Sub-
sampling
techniques
and
Sample
Preparation
• If core, whether cut or sawn and whether quarter, half or all core taken.
• If non-core, whether riffled, tube sampled, rotary split, etc and whether sampled wet or dry.
• For all sample types, the nature, quality and appropriateness of the sample preparation
technique.
• Quality control procedures adopted for all sub-sampling stages to maximise representivity of
samples.
Measures taken to ensure that the sampling is representative of the in situ material collected,
including for instance results for field duplicate/second-half sampling.
• Whether sample sizes are appropriate to the grain size of the material being sampled.
•
• Analysed samples were homogenised, pilot plant produced
kaolin product from the Great White and Chairlift Projects.
Andromeda Metals Limited | 11
Quality of
assay data and
laboratory tests
• The nature, quality and appropriateness of the assaying and laboratory procedures
used and whether the technique is considered partial or total.
• For geophysical tools, spectrometers, handheld XRF instruments, etc, the parameters
used in determining the analysis including instrument make and model, reading times,
calibrations factors applied and their derivation, etc.
• Nature of quality control procedures adopted (eg standards, blanks, duplicates,
external
• laboratory checks) and whether acceptable levels of accuracy (ie lack of bias) and
precision have been established.
Testwork Conditions and Analytical Methods
• The test conditions replicated those typically used in commercial ceramic
hotelware body and glaze production.
• Analytical methods selected were appropriate and yielded results with
acceptable accuracy and precision.
• Chemical composition was determined by AMG-Chrome, a UKAS-
accredited laboratory. Samples were fused into glass beads by mixing
with lithium tetraborate and heating to temperatures exceeding 1000°C,
followed by analysis using X-Ray Fluorescence (XRF). Loss on Ignition (LOI)
was measured at 1000°C.
• Particle size distribution of the products was measured via laser
diffraction using a Malvern Mastersizer.
• Sedigraph data provided by Andromeda was used to compare the <2 µm
size fraction of Andromeda’s products with other kaolin products
included in the testwork.
Ceramic Body Testwork
• Pressed discs from each body preparation were dried at 110°C and fired
in a gradient kiln across a range of typical commercial temperatures, from
1210°C to 1290°C.
• Fired discs were assessed for percentage contraction and water
absorption (WAB) at each firing temperature.
• Colour and brightness (CIE L*, a*, b* coordinates) were measured at
1290°C, representing the heat/work input typical of factory-scale tunnel
kiln operations.
• Colour measurements were conducted using a spectrophotometer.
Glaze Trials
• Standard and trial glaze formulations were applied to fired discs produced
using the Kaopearl recipe.
• Glaze suspensions were sprayed to achieve a consistent application
weight per square metre.
• Sprayed discs were oven-dried at 110°C and subsequently kiln-fired to
1080°C.
• Post-firing evaluations included visual inspection and measurement of L*,
a*, b* colour coordinates.
Andromeda Metals Limited | 12
Verification of
sampling and
assaying
• The verification of significant intersections by either independent or alternative
company personnel.
• The use of twinned holes.
• Documentation of primary data, data entry procedures, data verification, data
storage (physical and electronic) protocols.
• Discuss any adjustment to assay data.
• The tests were conducted at a commercial ceramic hotelware producer
in Stoke-on-Trent, UK, under the supervision of Ceramic Support Services.
The results were subsequently reviewed by First Test Minerals.
Location of
data points
• Accuracy and quality of surveys used to locate drill holes (collar and down-hole
surveys), trenches, mine workings and other locations used in Mineral Resource
estimation.
• Specification of the grid system used.
• Quality and adequacy of topographic control...
• Not applicable, the testwork was undertaken on manufactured
products.
Data spacing
and distribution
• Data spacing for reporting of Exploration Results.
• Whether the data spacing and distribution is sufficient to establish the degree of
geological and grade continuity appropriate for the Mineral Resource and Ore
Reserve estimation procedure(s) and classifications applied.
• Whether sample compositing has been applied...
• Not applicable, the testwork was undertaken on manufactured
products.
Orientation of
data in relation
to geological
structure
• Whether the orientation of sampling achieves unbiased sampling of possible
structures and the extent to which this is known, considering the deposit type.
• If the relationship between the drilling orientation and the orientation of key
mineralised structures is considered to have introduced a sampling bias, this
should be assessed and reported if material...
• Not applicable, the testwork was undertaken on manufactured
products.
Sample
security
• The measures taken to ensure sample security. • The Chain of Custody was managed by Andromeda. Double sealed
samples were electronically tracked during transport by commercial
courier contractors between processing facilities and analytical labs.
Audits or
reviews
• The results of any audits or reviews of sampling techniques and data. • The chemical composition of the products was analysed using X-Ray
Fluorescence (XRF) by both Bureau Veritas (BV) in Adelaide, South
Australia, and AMG-Chrome in the United Kingdom, a UKAS-accredited
laboratory. AMG reported slightly lower Fe2O3 values, though overall
results showed good correlation with those from BV.
Samples /
Chemistry SiO2 Al2O3 Fe2O3 TiO2 K2O CaO MgO Na2O LOI
CL-CRM001 AMG 47.28 37.68 0.48 0.11 0.56 <0.05 0.12 <0.05 13.65
CL-CRM-001 BV 47.68 37.80 0.55 0.11 0.58 0.04 0.06 <0.01 13.50
GW CRM™p AMG 46.89 38.21 0.37 0.37 0.43 <0.05 <0.05 <0.05 13.75
GW CRM™p BV 46.85 38.00 0.40 0.45 0.41 0.03 0.03 0.06 13.60
GW CRM™x AMG 46.78 38.81 0.26 0.20 0.19 <0.05 <0.05 <0.05 13.99
GW CRM™x BV 47.22 38.50 0.31 0.19 0.24 0.06 <0.01 <0.01 13.90
• Work undertaken by Ceramic Support Services was reviewed by First
Test Minerals.
Andromeda Metals Limited | 13
(Criteria listed in the preceding section also apply to this section.)
Mineral
tenement and
land tenure
status
• Type, reference name/number, location and ownership including agreements or
material issues with third parties such as joint ventures, partnerships, overriding
royalties, nativ
Share your feedback
Discover